Physical Elements Filters#

The following parameters are used during Prepare. They define thresholds for enabling or disabling the elements:

Name

Description

Unit 1

Beams

Minimum Length

The minimum length of beams to be considered relevant. All beams shorter than this value are disabled during Prepare but can be re-enabled manually.

Length

Minimum Width

The minimum width of beams to be considered relevant. All beams thinner than this value are disabled during Prepare but can be re-enabled manually.

Length

Columns

Minimum Height

The minimum height of columns to be considered relevant. All columns shorter than this value are disabled during Prepare but can be re-enabled manually.

Length

Minimum Section Dimension

The minimum width or height of columns to be considered relevant. All columns smaller than this value are disabled during Prepare but can be re-enabled manually.

Length

Walls

Minimum Length

The minimum length of walls to be considered relevant. All walls shorter than this value are disabled during Prepare but can be re-enabled manually.

Length

Minimum Thickness

The minimum thickness of walls to be considered relevant. All walls thinner than this value are disabled during Prepare but can be re-enabled manually.

Length

1