BE33: Work Laws in case of Fire for Concrete and Structural Steel

This benchmark is concerned with the validation of the structural analysis in case of fire with respect to the general calculation method according to DIN EN 1992-1-2. Therefore test case 5 is employed as presented in Annex CC of the standard DIN EN 1992-1-2/NA:2010-03 [35]. In this example the validation of the change in length of structural steel and concrete in compression, for the model shown in the figure, at
varying temperature and load capacity levels, is investigated.This is one example of our Verification Manual. You can find the whole manual in SSD and TEDDY via menue Help > Verification Manual, the input data files in TEDDY via menue Help> examples... > verification.

Type Benchmark Example
Productgroup Structural / Dynamics / FEA
Applications General
Date 27.06.2014
Keywords Benchmark example, quality assurance